{"id":11547,"date":"2020-01-26T03:42:13","date_gmt":"2020-01-26T03:42:13","guid":{"rendered":"https:\/\/essential.construction\/cnstrctr\/glossary\/post-tension\/"},"modified":"2026-11-03T10:08:50","modified_gmt":"2026-11-03T17:08:50","slug":"post-tension","status":"publish","type":"glossary","link":"https:\/\/essential.construction\/academy\/glossary\/post-tension\/","title":{"rendered":"Post Tension"},"content":{"rendered":"<p><strong>Post tension<\/strong> (post-tensioning) is a method of reinforcing a concrete slab or beam with high-strength steel tendons that are stretched with hydraulic jacks after the concrete has gained enough strength. The tension compresses the concrete, allowing thinner slabs and longer spans, but cutting or coring a post-tensioned slab requires scanning first.<\/p>\n<p>Post-tensioned (PT) concrete is common in parking garages, condo and office towers, transfer beams, bridges and slabs-on-grade on expansive soils. On site the tendons are often called PT cables or rods.<\/p>\n<h2>How post-tensioning works<\/h2>\n<ol>\n<li><strong>Layout:<\/strong> tendons are placed to the PT shop drawings, usually draped high over supports and low at midspan so the force counteracts the load.<\/li>\n<li><strong>Anchors:<\/strong> each tendon has an anchor at both ends. The <em>dead end<\/em> is fixed; the <em>live end<\/em> is where the jack grips it.<\/li>\n<li><strong>Pour:<\/strong> concrete is placed around the tendons, which are not yet stressed.<\/li>\n<li><strong>Stressing:<\/strong> once test results show the concrete has reached the strength the engineer specifies, a crew stretches each tendon with a hydraulic jack and locks it off with wedges. Elongations are measured and recorded.<\/li>\n<li><strong>Finishing:<\/strong> tendon tails are cut off and the stressing pockets are filled to protect the anchors.<\/li>\n<\/ol>\n<p>Because the concrete is held in compression, it resists cracking and deflection better than conventionally reinforced concrete of the same depth. PT slabs still contain some regular <a href=\"https:\/\/essential.construction\/academy\/glossary\/rebar\/\">rebar<\/a>.<\/p>\n<h2>Bonded vs unbonded post-tensioning<\/h2>\n<table>\n<thead>\n<tr>\n<th><\/th>\n<th>Unbonded<\/th>\n<th>Bonded<\/th>\n<\/tr>\n<\/thead>\n<tbody>\n<tr>\n<td>Tendon<\/td>\n<td>Single greased strand in a plastic sheath<\/td>\n<td>One or more strands in a metal or plastic duct<\/td>\n<\/tr>\n<tr>\n<td>After stressing<\/td>\n<td>Strand can move inside the sheath<\/td>\n<td>Duct is filled with grout, bonding steel to concrete<\/td>\n<\/tr>\n<tr>\n<td>Common use<\/td>\n<td>Building slabs in North America, slabs-on-grade<\/td>\n<td>Bridges, heavy beams, and building slabs in many other markets<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<h2>Post-tensioning vs pre-tensioning<\/h2>\n<p>Both are forms of prestressed concrete. <strong>Pre-tensioning<\/strong> stretches strands in a casting bed before the concrete is poured, which is how precast hollow-core planks and many precast girders are made. <strong>Post-tensioning<\/strong> stresses the tendons on site after the pour, so it suits cast-in-place work.<\/p>\n<h2>Drilling, coring and cutting PT slabs<\/h2>\n<p>A stressed tendon holds a large amount of energy. If it is cut it can lose its force suddenly, damage the slab and injure people. Before any coring, anchor drilling or saw cutting:<\/p>\n<ul>\n<li>Scan the area with ground-penetrating radar (GPR) or X-ray and mark tendons on the surface.<\/li>\n<li>Get the structural engineer&#8217;s approval for the hole location and size.<\/li>\n<li>Use a permit system so no one drills a PT slab without sign-off.<\/li>\n<\/ul>\n<p>Our <a href=\"https:\/\/essential.construction\/academy\/tutorials\/saw-cutting-and-coring\/\">saw cutting and coring guide<\/a> covers scanning and approvals in more detail.<\/p>\n<h2>Related terms<\/h2>\n<ul>\n<li><a href=\"https:\/\/essential.construction\/academy\/glossary\/rebar\/\">Rebar<\/a><\/li>\n<li><a href=\"https:\/\/essential.construction\/academy\/glossary\/formwork\/\">Formwork<\/a><\/li>\n<li><a href=\"https:\/\/essential.construction\/academy\/glossary\/shoring\/\">Shoring<\/a><\/li>\n<li><a href=\"https:\/\/essential.construction\/academy\/glossary\/camber\/\">Camber<\/a><\/li>\n<\/ul>\n<h2>Related templates and guides<\/h2>\n<ul>\n<li><a href=\"https:\/\/essential.construction\/files\/construction\/safety\/work-permit-post-tensioning\/\">Work permit: post tensioning<\/a><\/li>\n<li><a href=\"https:\/\/essential.construction\/files\/construction\/logistics\/work-permit-drilling-coring-and-cutting\/\">Work permit: drilling, coring and cutting<\/a><\/li>\n<li><a href=\"https:\/\/essential.construction\/files\/construction\/quality\/concrete-pre-pour-checklist-template\/\">Concrete pre-pour checklist template<\/a><\/li>\n<li><a href=\"https:\/\/essential.construction\/academy\/tutorials\/cold-weather-concrete\/\">Working with concrete in cold weather<\/a><\/li>\n<\/ul>\n<h2>Frequently asked questions<\/h2>\n<h3>Can you drill into a post-tensioned slab?<\/h3>\n<p>Only after the tendons have been located. Scan the slab with GPR or X-ray, mark the tendons, and get the engineer&#8217;s approval for the hole location. Hitting a stressed tendon can injure workers, damage the structure and lead to costly repairs, so never core or drill blind.<\/p>\n<h3>What is the difference between pre-tensioning and post-tensioning?<\/h3>\n<p>Pre-tensioning stresses the steel strands before the concrete is cast, usually in a precast plant, and the concrete bonds directly to the strand. Post-tensioning places strands in sheathing or ducts, casts the concrete, and stresses the tendons on site once the concrete is strong enough.<\/p>\n<h3>Are post tension cables and post tension rods the same thing?<\/h3>\n<p>On site people often call tendons cables or rods. Most building tendons are seven-wire steel strand, not solid rods, though some post-tensioning systems do use high-strength threaded bars. The structural drawings and the PT supplier&#8217;s shop drawings show which system is used.<\/p>\n<h3>How long do post-tension slabs last?<\/h3>\n<p>A well-designed and well-built post-tensioned slab can last as long as other reinforced concrete structures. Durability depends on keeping water and chlorides away from the tendons and anchors. Older parking garages with poor protection are where corroded or failed tendons are most often found.<\/p>\n","protected":false},"excerpt":{"rendered":"<p>Post tension (post-tensioning) is a method of reinforcing a concrete slab or beam with high-strength steel tendons that are stretched with hydraulic jacks after the<\/p>\n","protected":false},"author":1,"featured_media":16891,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"footnotes":""},"glossary-categories":[466],"glossary-tags":[528,554,555,556,557,558],"class_list":["post-11547","glossary","type-glossary","status-publish","has-post-thumbnail","hentry","glossary-categories-division-03-concrete","glossary-tags-concrete","glossary-tags-concrete-rebar","glossary-tags-concrete-reinforcement","glossary-tags-concrete-supply","glossary-tags-post-tension","glossary-tags-rebar"],"_links":{"self":[{"href":"https:\/\/essential.construction\/academy\/wp-json\/wp\/v2\/glossary\/11547","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/essential.construction\/academy\/wp-json\/wp\/v2\/glossary"}],"about":[{"href":"https:\/\/essential.construction\/academy\/wp-json\/wp\/v2\/types\/glossary"}],"author":[{"embeddable":true,"href":"https:\/\/essential.construction\/academy\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/essential.construction\/academy\/wp-json\/wp\/v2\/comments?post=11547"}],"version-history":[{"count":2,"href":"https:\/\/essential.construction\/academy\/wp-json\/wp\/v2\/glossary\/11547\/revisions"}],"predecessor-version":[{"id":20376,"href":"https:\/\/essential.construction\/academy\/wp-json\/wp\/v2\/glossary\/11547\/revisions\/20376"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/essential.construction\/academy\/wp-json\/wp\/v2\/media\/16891"}],"wp:attachment":[{"href":"https:\/\/essential.construction\/academy\/wp-json\/wp\/v2\/media?parent=11547"}],"wp:term":[{"taxonomy":"glossary-categories","embeddable":true,"href":"https:\/\/essential.construction\/academy\/wp-json\/wp\/v2\/glossary-categories?post=11547"},{"taxonomy":"glossary-tags","embeddable":true,"href":"https:\/\/essential.construction\/academy\/wp-json\/wp\/v2\/glossary-tags?post=11547"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}